Owner's manual

Appendix F - Variables Grouped by Fluidmove Activity F-77
F.29 DJ Offset CalibrationRemote Command
DJ Offset Calibration is a script command used during machine setup to calibrate jet valve start/stop timing to the actual dispensed line. The remote
command uses the DJ Unassisted Offset script routine which does not require operator interaction.
The SECS/GEM host can start this process with a remote command sent to the client machine. The following tables describe the SECS/GEM remote
command and variables related DJ Offset Calibration.
Table F.29-1 DJ Offset Calibration Remote Command
Remote Command CEID
Related Data
Variables
Description
Remote Command String =
“DJ OFFSET CALIBRATION
Remote control command may include the
valve name and number in the command
parameters. (SECS/GEM S2F41 format)
No parameters will default to Valve 1.
6538
6539
6540
6541
6574
6575
6576
6577
6578
Remote control command to start DJ Offset Calibration.
3749 ce_DJOffsetCalibrationPass
3773 ce_DJOffsetCalibrationFail
The remote command can include the valve name and number parameters:
(SECS/GEM S2F41 format, Remote Command with Parameters) No parameters in the command message will default to Valve 1.