Owner's manual

Appendix F - Variables Grouped by Fluidmove Activity F-65
F.25 Prime – Remote Command
Prime is a script command used during machine setup to valves. The SECS/GEM host can start this process with a remote command sent to the client
machine. The following tables describe the SECS/GEM remote command and variables related Prime remote command.
Table F.25-1 PrimeRemote Command
Remote Command CEID
Related Data
Variables
Description
Remote Command String =
“PRIME”
Remote control command may include the
valve and scale name and number in the
command parameters. (SECS/GEM
S2F41 format)
No parameters will default to Valve 1,
Scale 1.
Remote control command to start Prime process.
3741 ce_PrimePass
3767 ce_PrimeFail
The remote command can include the valve and scale name and number parameters:
(SECS/GEM S2F41 format, Remote Command with Parameters)
No parameters in the command message will default to Valve 1, Scale 1.
Table F.25-2 Prime Variables
Variable Name ID
Storage
Type
SECS
Type
CEID Description
ce_Prime -- -- -- 3741 Collection event for priming valves.