Owner's manual
F-62 Appendix F - Variables Grouped by Fluidmove Activity
F.24 Locate Service Station – Remote Command
The Locate Service Station process will locate each fiducial and perform a height sense on the purge cup. Once this is complete, the tactile center, the
substrate corners, and the purge location are defined.
SECS/GEM host can start this process with a remote command sent to the client machine. The following tables describe the SECS/GEM remote command
and variables related Locate Service Station.
Table F.24-1 Locate Service Station – Remote Command
Collection Event Name CEID
Related Data and
Status Variables
Description
Remote Command String =
“LOCATE SERVICE STATION”
Remote control command may include the
valve name and number in the command
parameters. (SECS/GEM S2F41 format)
No parameters will default to Valve 1.
Remote control command to start Locate Service Station process.
3742 ce_LocateServiceStationPass
3768 ce_LocateServiceStationFail
Table F.24-2 Locate Service Station - Equipment Constants and Collection Events
Variable Name ID
Storage
Type
SECS
Type
Related
CEID
Description
c_ServiceStationFidXY_1 6526 A40 EC 3742 Service Station Fid 1 location.
c_ServiceStationFidXY_2 6527 A40 EC 3742 Service Station Fid 2 location.
ce_LocateServiceStation 3742 --- --- ---
Collection event triggered when Locate Service
Station is complete.