Owner's manual
Appendix F - Variables Grouped by Fluidmove Activity F-55
F.22 Needle XY Offsets – Remote Command
Needle XY Offsets is a script command used during machine setup to locate the XY offset of the Needle/Jet relative to the camera. The SECS/GEM host
can start this process with a remote command sent to the client machine. The following tables describe the SECS/GEM remote command and variables
related Needle XY Offsets.
Table F.22-1 Needle XY Offsets – Remote Command
Remote Command CEID
Related Data
Variables
Description
Remote Command String =
“NEEDLE XY OFFSETS” or “NEEDLE XY
OFFSETS NO PURGE”
Remote control command may include the
valve and scale name and number in the
command parameters. (SECS/GEM
S2F41 format)
No parameters will default to Valve 1,
Scale 1.
6295
Remote control command to start Height Sense XY Offsets with or
without valve purge during the process.
3736 ce_NeedleXYOffsetsPass
3765 ce_NeedleXYOffsetsFail
The remote command can include the valve and scale name and number parameters:
(SECS/GEM S2F41 format, Remote Command with Parameters)
No parameters in the command message will default to Valve 1, Scale 1.
Table F.22-2 Needle XY Offsets Variables
Variable Name ID
Storage
Type
SECS
Type
CEID Description
c_XYNeedleOffset_V1 6295 A40 EC 3736 Needle offset for Valve 1.
c_XYNeedleOffset_V2 6543 A40 EC 3736 Needle Offset for valve 2.