Owner's manual
F-52 Appendix F - Variables Grouped by Fluidmove Activity
F.21 Height Sense XY Offsets – Remote Command
Height Sense XY Offsets is a script command used during machine setup to locate the XY offset of the height sensor probe or laser beam relative to the
valve. The SECS/GEM host can start this process with a remote command sent to the client machine. The following tables describe the SECS/GEM
remote command and variables related Height Sense XY Offsets.
Table F.21-1 Height Sense XY Offsets – Remote Command
Remote Command CEID
Related Data
Variables
Description
Remote Command String =
“HS XY OFFSETS”
Remote control command may include the
valve and scale name and number in the
command parameters. (SECS/GEM
S2F41 format)
No parameters will default to Valve 1,
Scale 1.
6296 Remote control command to start Height Sense XY Offsets.
3735 ce_HSXYOffsetsPass
3763 ce_HSXYOffsetsFail
The remote command can include the valve and scale name and number parameters:
(SECS/GEM S2F41 format, Remote Command with Parameters)
No parameters in the command message will default to Valve 1, Scale 1.
Table F.21-2 Height Sense XY Offsets –Related Equipment Constants
Variable Name ID
Storage
Type
SECS
Type
CEID Description
c_NdltoHSoffset_V1 6296 A40 EC None Needle to height sense offset for Valve 1.