Owner's manual
Appendix F - Variables Grouped by Fluidmove Activity F-49
F.20 Run PSS File – Remote Command
Run PSS File remote command to run a prompted setup script file on dispenser. The requested PSS file must already be loaded onto the dispensing
machine in the Fluidmove directory or an error will result. The SECS/GEM host can start this process with a remote command sent to the client machine.
The following tables describe the SECS/GEM remote command and variables related to Run PSS File process.
Table F.20-1 Run PSS File – Remote Command
Remote Command CEID
Related Data and
Status Variables
Description
Remote Command String =
“RUN PSS FILE”
Remote control command includes the
filename and valve number in the
command parameters. (SECS/GEM
S2F41 format)
No parameters will default to Valve 1,
Scale 1.
---
Remote command runs a prompted setup script file from the host
command.
4001 PromptedSetupStarted
4002 PromptedSetupCompleted
The remote command includes the PSS filename and valve number parameters:
(SECS/GEM S2F41 format, Remote Command with Parameters)
No valve parameter in the command message will default to Valve 1