Owner's manual
Appendix F - Variables Grouped by Fluidmove Activity F-43
Table F.18-2 Dispense Weight Verification – Data Variables and Collection Events
Variable Name ID
Storage
Type
SECS
Type
CEID Description
DWVRESULT 408 U2 DV 4020 DWV result status.
DWVMEASUREDAVG 416 F8 DV 4020
Average measured weight of all dispenses during
the dispense weight verification procedure.
DWVSTATUS 639 U2 DV
3721
3722
Return status of Dispense Weight Verification
process.
ce_DWVComplete_V1 3721 -- CE --
Collection event is triggered when DWV process is
complete. (Valve 1)
ce_DWVComplete_V2 3722 -- CE --
Collection event is triggered when DWV process is
complete. (valve 2)
Usage Scenario
The SECS/GEM host can read and change the dispense weight target value DWVTarget, 410, before starting the DWV procedure. The host starts the
DWV procedure by sending the remote command DWV. After the DWV procedure is finished, collection events 4020 and 3721 or 3722 are triggered and
DWV measured average variable 416 is updated for the host.