F-38 Appendix F - Variables Grouped by Fluidmove Activity
Table F.17-2 Flow Rate Calibration Remote Command Related Data Variables and Collection Events
Variable Name ID
Storage
Type
SECS
Type
CEID Description
FlowRate1 400 F8 DV 3730 Flow Rate value (Valve 1)
FlowRate2 403 F8 DV 3731 Flow Rate value (valve 2)
ce_FlowRateCalibComplete_V1 3730 --- CE ---
Collection event triggered when Valve 1 Flow Rate
Calibration process is completed
ce_FlowRateCalibComplete_V2 3731 --- CE ---
Collection event triggered when valve 2 Flow Rate
Calibration process is completed
FlowRateCalibStatus 640 U2 DV
3730
3731
Return status of Flow Rate Calibration process.
(Valve 1&2)
Table F.17-3 Flow Rate Calibration Results Status
Return
Value
Description
0 Passed
1 Failed Setup Error
2 Failed Out-of-Range
5 Failed User Aborted
6 Failed Other