Owner's manual
F-34 Appendix F - Variables Grouped by Fluidmove Activity
F.16 Calibrated Process Jetting (CPJ) – Remote Command
Check Calibrated Process Jetting is a process to check dispensed fluid flow rate accuracy and consistency. This is accomplished by taking several
sequential dispense measurements and computing the average of the weight data and valve flow rate. The SECS/GEM host can start this process with a
remote command sent to the client machine. The following tables describe the SECS/GEM remote command and variables relating to Check Calibrated
Process Jetting.
Table F.16-1 Calibrated Process Jetting (CPJ) - Remote Command
Remote Command CEID
Related Data and
Status Variables
Description
Remote Command String =
“CHECKCPJ”
Remote control command may include the
valve and scale name and number in the
command parameters. (SECS/GEM
S2F41 format)
No parameters will default to Valve 1,
Scale 1.
Valve 1 = 6504
Valve 2 = 6505
Status = 420
Remote control command to start Calibrated Process Jetting Check.
(mg/dot flowrate) The actual valve flow rate is not changed.
3701 ce_CPJCheckComplete_V1Pass
3780 ce_CPJCheckComplete_V1Fail
3702 ce_CPJCheckComplete_V2Pass
3781 ce_CPJCheckComplete_V2Fail
The remote command can include the valve and scale name and number parameters:
(SECS/GEM S2F41 format, Remote Command with Parameters)
No parameters in the command message will default to Valve 1, Scale 1.