Owner's manual

F-30 Appendix F - Variables Grouped by Fluidmove Activity
F.11 LMO Height Sense
Table F.11-1 LMO Height Sense Equipment Constants
Variable Name ID
SECS
Type
Storage
Type
Description
c_LmoHeightSenseEnabled 6506 A[4] ASCII
Enables / disables LMO Height Sense.
Set variable string to “ON” to enable LMO Height Sense.
Set variable string to “OFF” to disable LMO Height Sense.
(FmConfig.ini entry: Height Sense =)
c_LmoHeightSenseLane1 6517 A[30] FLT
Height sense value used for Lane 1 when LMO Height Sense is active.
NOTE: THIS VALUE IS IN 0.1 MIL UNITS
(FmConfig.ini entry: Height Sense Value Lane 1=)
c_LmoHeightSenseLane2 6518 A[30] FLT
Height sense value used for Lane 2 when LMO Height Sense is active.
NOTE: THIS VALUE IS IN 0.1 MIL UNITS
(FmConfig.ini entry: Height Sense Value Lane 2=)
LmoHeightSenseLane1UserUnits 7703 A[30] FLT
Height sense value used for Lane 1 when LMO Height Sense is active.
NOTE: THIS VALUE IS IN USER UNITS (inch, mm, …)
LmoHeightSenseLane2UserUnits 7704 A[30] FLT
Height sense value used for Lane 2 when LMO Height Sense is active.
NOTE: THIS VALUE IS IN USER UNITS (inch, mm, … )
Table F.11-2 LMO Height Sense - Collection Events
Collection Event Name CEID
Related Data
Variables
Description
ce_LmoHsEnabled 3715
Collection event that is triggered when Local Machine Offsets Height
Sense has been enabled.
ce_LmoHsDisabled 3716
Collection event that is triggered when Local Machine Offsets Height
Sense has been disabled.
ce_LmoHsModified 3717
Collection event that is triggered when the Local Machine Offsets Height
Sense has been modified.