Owner's manual
F-28 Appendix F - Variables Grouped by Fluidmove Activity
Table F.9-1 LMO Workpiece Origin - Collection Events (Continued)
Collection Event Name CEID
Related Data
Variables
Description
ce_LmoWpAlignFailed 3714 7705
Collection event that is triggered after Local Machine Offsets Workpiece
Origin realignment has completed and did not succeed.
ce_LmoWpFidFound_1 3718
7706
7708
Collection event triggered when fiducial 1 of Local Machine Workpiece is
found.
ce_LmoWpFidFound_2 3719
7707
7709
Collection event triggered when fiducial 2 of Local Machine Workpiece is
found.
ce_LmoWpFidNotFound_1 3760
7706
7708
Collection event triggered when fiducial 1 of Local Machine Workpiece is
not found.
ce_LmoWpFidNotFound_2 3761
7707
7709
Collection event triggered when fiducial 2 of Local Machine Workpiece is
not found.
Table F.9-2 LMO Workpiece Origin – Data Variables
Data Variable Name ID
SECS
Type
Storage
Type
Fluid File Entry
LmoWpFrame 7705 A[50] FLT,FLT,FLT
Current X, Y,Theta origin of the Local Machine Workpiece Offset name
selected. If LMO workpiece is not enabled or the LMO name selected is
not valid, this string will contain “-1, -1, -1”. These values are in user
units.
LmoWpFidFoundXY_1 7706 A[ 40] FLT,FLT
Fiducial 1 XY location (in machine units) found during LMO workpiece re-
alignment. Valid after collection event 3718 or 3760 occurs.
Note that this is the “expected” location for CEID 3760.
LmoWpFidFoundXY_2 7707 A[40] FLT,FLT
Fiducial 2 XY location (in machine units) found during LMO workpiece re-
alignment. Valid after collection event 3719 or 3761occurs.
Note that this is the “expected” location for CEID 3761.
LmoWpFidFoundScore_1 7708 I2 INT
Fiducial 1 found score during LMO workpiece re-alignment. Valid after
collection event 3718 or 3760 occurs.
LmoWpFidFoundScore_2 7709 I2 INT
Fiducial 2 found score during LMO workpiece re-alignment. Valid after
collection event 3719 or 3761 occurs.