Owner's manual
F-24 Appendix F - Variables Grouped by Fluidmove Activity
Table F.8-9 Fluid File - Data Variables (Continued)
Data Variable Name ID
SECS
Type
Storage
Type
Fluid File Entry
fc_DJFlowCalibrationMinWeight 11206 A[30] FLT DJ Flow Calibration Min Weight (mg)
fc_PercentofMaxDJWeightControlSpeed 11207 A[30] FLT Percent of Max DJ Weight-Control Speed
fc_SetPurgeOnTimer 11208 I4 INT Set Purge On Timer
fc_SetFlowRateOnTimer 11209 I4 INT Set FlowRate On Timer
fc_PurgeonRunCount 11210 I4 INT Purge on Run Count
fc_FlowRateCalibrationonRunCount 11211 I4 INT Flow Rate Calibration on Run Count
fc_FlowCalibrationDispenses 11212 I4 INT Flow Calibration Dispenses
fc_FlowCalibrationIntervalDelay 11213 A[30] FLT Flow Calibration Interval Delay
fc_MinimumFlowRate 11214 A[30] FLT Minimum Flow Rate
fc_MaximumFlowRate 11215 A[30] FLT Maximum Flow Rate
fc_Fluidname 11216 A[100] ASCII Fluid name
fc_PotLifeEnabled 11217 A[4] ASCII Pot Life Enabled
fc_Potlife 11218 A[30] FLT Pot life
fc_Potlifenotify 11219 A[30] FLT Pot life notify
fc_ScaleBias 11220 A[30] FLT Scale Bias (%)
fc_ZeroScaleXOffset 11221 A[30] FLT Zero Scale X Offset
fc_ZeroScaleYOffset 11222 A[30] FLT Zero Scale Y Offset
fc_ZeroScaleZOffset 11223 A[30] FLT Zero Scale Z Offset
fc_FlowCalibrationPreMove 11224 A[100] ASCII Flow Calibration Pre-Move
fc_FlowCalibrationPostMove 11225 A[100] ASCII Flow Calibration Post-Move
fc_FilletBias 11226 A[30] Fillet Bias (%)
fc_BoardsafterLowFluidSensed 11227 I4 INT Boards after Low Fluid Sensed
fc_LowFluidBoardsToGo 11228 I4 INT Low Fluid Boards To Go
fc_EnableLowFluidCheck 11229 A[4] ASCII Enable Low Fluid Check
fc_LowFluidCheck 11230 I4 INT Low Fluid Check
fc_DefaultWeightofPrimedFluid 11231 A[30] FLT Default Weight of Primed Fluid (mg)
fc_Initialsyringeweight 11232 A[30] FLT Initial syringe weight (mg)
Fc_Warningsyringeweight 11233 A[30] FLT Warning syringe weight (mg)
fc_Criticalsyringeweight 11234 A[30] FLT Critical syringe weight (mg)