Owner's manual
Table E-1 SECS/GEM Remote Commands (Continued)
Appendix E - SECS/GEM Remote Commands E-7
Remote Command Description
Optional
Parameters
Return Status Code Description
“RESUME”
Resume production run
See Appendix F – “RESUME”
remote command
None
0x00 Command received successfully and is executing
0x02 Not in Production window
0x40 Not in REMOTE mode
0x41 Program not paused – cannot execute command
“RUN PSS FILE”
Run Prompted Setup Script file
See Appendix F – “RUN PSS FILE”
remote command
Prompted
Setup Script
Filename
Valve 1
Valve 2
0x00 Command received successfully and is executing
0x01 Command invalid in current configuration
0x02 Not in Production window
0x03 Command has a bad parameter
0x40 Not in REMOTE mode
0x41 Program running – cannot execute command
0x43 PP Select file not found
“START”
Start production run
See Appendix F – “START” remote
command
None
0x00 Command received successfully and is executing
0x02 Not in Production window
0x40 Not in REMOTE mode
0x41 Program running – cannot execute command
0x46 Production start blocked by RFID validation
“STOP”
Stop production run
See Appendix F – “STOP” remote
command
None
0x00 Command received successfully and is executing
0x02 Not in Production window
0x40 Not in REMOTE mode
0x41 Program not running – cannot execute command
“TEACH SCALE”
Teach scale location
See Appendix F – “TEACH SCALE”
remote command
Valve 1
Valve 2
Scale 1
Scale 2
0x00 Command received successfully and is executing
0x01 Command invalid in current configuration
0x02 Not in Production window
0x03 Command has a bad parameter
0x40 Not in REMOTE mode
0x41 Program running – cannot execute command