Owner's manual
Table E-1 SECS/GEM Remote Commands (Continued)
E-6 Appendix E - SECS/GEM Remote Commands
Remote Command Description
Optional
Parameters
Return Status Code Description
“PRELIM NEEDLE TO CAMERA”
Start preliminary Needle to Camera
Offset setup
See Appendix F – “PRELIM
NEEDLE TO CAMERA” remote
command
Valve 1
Valve 2
0x00 Command received successfully and is executing
0x01 Command invalid in current configuration
0x02 Not in Production window
0x03 Command has a bad parameter
0x40 Not in REMOTE mode
0x41 Program running – cannot execute command
“PRIME”
Prime valve
See Appendix F – “PRIME” remote
command
Valve 1
Valve 2
0x00 Command received successfully and is executing
0x01 Command invalid in current configuration
0x02 Not in Production window
0x03 Command has a bad parameter
0x40 Not in REMOTE mode
0x41 Program running – cannot execute command
“PURGE”
Purge Valve
See Appendix F – “PURGE” remote
command
Valve 1
Valve 2
0x00 Command received successfully and is executing
0x01 Command invalid in current configuration
0x02 Not in Production window
0x03 Command has a bad parameter
0x40 Not in REMOTE mode
0x41 Program running – cannot execute command
“REMOTE”
Change SECS/GEM control state to
“Remote” mode
See Appendix F – “REMOTE”
remote command
None 0x00 Command received successfully and is executing
“RESTART_APPLICATION”
Restart Fluidmove application
See Appendix F –
“RESTART_APPLICATION” remote
command
None
0x00 Command received successfully and is executing
0x02 Not in Production window
0x40 Not in REMOTE mode
0x41 Program running – cannot execute command