Owner's manual

Table E-1 SECS/GEM Remote Commands (Continued)
Appendix E - SECS/GEM Remote Commands E-5
Remote Command Description
Optional
Parameters
Return Status Code Description
“NEEDLE XY OFFSETS”
“NEDDLE XY OFFSETS NO
PURGE”
Start Needle XY Offsets setup with
or without purge during the process.
See Appendix F “NEEDLE XY
OFFSETS” and “NEEDLE XY
OFFSETS NO PURGE” remote
commands
Valve 1
Valve 2
0x00 Command received successfully and is executing
0x01 Command invalid in current configuration
0x02 Not in Production window
0x03 Command has a bad parameter
0x40 Not in REMOTE mode
0x41 Program running cannot execute command
“NEEDLE Z OFFSETS”
Start Needle Z Offset setup
See Appendix F “NEEDLE Z
OFFSETS” remote command
Valve 1
Valve 2
0x00 Command received successfully and is executing
0x01 Command invalid in current configuration
0x02 Not in Production window
0x03 Command has a bad parameter
0x40 Not in REMOTE mode
0x41 Program running cannot execute command
“PAUSE”
Pause production run
See Appendix F “PAUSE” remote
command
None
0x00 Command received successfully and is executing
0x01 Command invalid in current configuration
0x02 Not in Production window
0x40 Not in REMOTE mode
0x41 Program is paused cannot execute command
“PP-SELECT
Load Recipe file
See Appendix F “PP-SELECT
remote command
Lot ID
Lot Name
PP ID
PP Name
0x00 Command received successfully and is executing
0x01 Command invalid in current configuration
0x02 Not in Production window
0x03 Command has a bad parameter
0x40 Not in REMOTE mode
0x41 Program running cannot execute command