Owner's manual
Table E-1 SECS/GEM Remote Commands
Appendix E - SECS/GEM Remote Commands E-2
Remote Command Description
Optional
Parameters
Return Status Code Description
“ABORT”
Abort production run
See Appendix F – “ABORT” remote
command
None
0x00 Command received successfully and is executing
0x02 Not in Production window
0x40 Not in REMOTE mode
0x41 Program running – cannot execute command
“CHECKCPJ”
Check Calibrated Process Jetting
for DJ valve
See Appendix F – “CHECKCPJ”
remote command
Valve 1
Valve 2
Scale 1
Scale 2
0x00 Command received successfully and is executing
0x01 Command invalid in current configuration
0x02 Not in Production window
0x03 Command has a bad parameter
0x40 Not in REMOTE mode
0x41 Program running – cannot execute command
“DJ OFFSET CALIBRATION”
Start DJ Offset calibration
See Appendix F – “DJ OFFSET
CALIBRATION” remote command
Valve 1
Valve 2
0x00 Command received successfully and is executing
0x01 Command invalid in current configuration
0x02 Not in Production window
0x03 Command has a bad parameter
0x40 Not in REMOTE mode
0x41 Program running – cannot execute command
“DJ9K VACUUM ASSISTED
PRIME”
Start DJ9K Vacuum Assisted Prime
See Appendix F – “DJ9K VACUUM
ASSISTED PRIME” remote
command
Valve 1
Valve 2
0x00 Command received successfully and is executing
0x01 Command is not recognized
0x02 Not in Production window
0x03 Command has a bad parameter
0x40 Not in REMOTE mode
0x41 Program running – cannot execute command
“DWV”
Start Dispense Weight Verification
See Appendix F – “DWV” remote
command
Valve 1
Valve 2
Scale 1
Scale 2
0x00 Command received successfully and is executing
0x01 Command invalid in current configuration
0x02 Not in Production window
0x03 Command has a bad parameter
0x40 Not in REMOTE mode
0x41 Program running – cannot execute command