Owner's manual

Table E-1 SECS/GEM Remote Commands
Appendix E - SECS/GEM Remote Commands E-2
Remote Command Description
Optional
Parameters
Return Status Code Description
“ABORT
Abort production run
See Appendix F “ABORT” remote
command
None
0x00 Command received successfully and is executing
0x02 Not in Production window
0x40 Not in REMOTE mode
0x41 Program running cannot execute command
“CHECKCPJ”
Check Calibrated Process Jetting
for DJ valve
See Appendix F “CHECKCPJ”
remote command
Valve 1
Valve 2
Scale 1
Scale 2
0x00 Command received successfully and is executing
0x01 Command invalid in current configuration
0x02 Not in Production window
0x03 Command has a bad parameter
0x40 Not in REMOTE mode
0x41 Program running cannot execute command
“DJ OFFSET CALIBRATION
Start DJ Offset calibration
See Appendix F “DJ OFFSET
CALIBRATION” remote command
Valve 1
Valve 2
0x00 Command received successfully and is executing
0x01 Command invalid in current configuration
0x02 Not in Production window
0x03 Command has a bad parameter
0x40 Not in REMOTE mode
0x41 Program running cannot execute command
“DJ9K VACUUM ASSISTED
PRIME”
Start DJ9K Vacuum Assisted Prime
See Appendix F “DJ9K VACUUM
ASSISTED PRIME” remote
command
Valve 1
Valve 2
0x00 Command received successfully and is executing
0x01 Command is not recognized
0x02 Not in Production window
0x03 Command has a bad parameter
0x40 Not in REMOTE mode
0x41 Program running cannot execute command
DWV
Start Dispense Weight Verification
See Appendix F “DWV” remote
command
Valve 1
Valve 2
Scale 1
Scale 2
0x00 Command received successfully and is executing
0x01 Command invalid in current configuration
0x02 Not in Production window
0x03 Command has a bad parameter
0x40 Not in REMOTE mode
0x41 Program running cannot execute command