Owner's manual
Table B-1 Collection Events (Continued)
B-14 Appendix B - Collection Events
Collection Event Name CEID
Related
Data Variables
Description
ce_ScaleOverflow_S2 4027
6704, 6706, 6708, 6710,
6712, 6714, 6716
Collection event when scale 2 overflow condition has occurred. The
operator has been notified that scale 2 has met or exceeded maximum
weight capacity.
ce_ScaleOverflowWarning_S2 4028
6704, 6706, 6708, 6710,
6712, 6714, 6716
Collection event when scale 2 overflow warning has been issued. The
operator has been notified that scale 2 has reached the warning level
weight capacity.
ce_ScaleOverflowReset_S2 4029
6704, 6706, 6708, 6710,
6712, 6714, 6716
Collection event when an operator has manually reset the overflow
parameters from the scale configuration menu or has indicated that the
cup has been replaced in response to a warning or overflow message.
HeaterMonitorTimeout 5001 None
Collection event when the heaters at the dispensing location failed to
reach the specified temperature range within the timeout period.
HeaterMonitorSkipped 5002 None
Collection event when the Operator has selected to skip the temperature
monitoring and proceed to dispensing.
HeaterMonitorAborted 5003 None
Collection event when the Operator has selected to abort the
temperature monitoring and aborted the run.
PeriodicPurge1 5004 None
Collection event when a periodical purging of the needle for Valve 1 has
been performed.
PeriodicFlowrateMeasurement1 5005 None
Collection event when a periodical flow rate measurement for Valve 1
has been performed.
PotLifeWarning1 5006 None
Collection event when the pot life of the dispensing material for Valve 1
has reached a warning level.
PotLifeExpire1 5007 None
Collection event when the pot life of the dispensing material for Valve 1
has expired.
AwaitingRecoveryCommand 5008 None
Collection event when the system has queried the Operator to recover
the previous run.
OperatorAckedTerminalMsg 5009 None
Used by GEM drivers
Collection event when the Operator acknowledged a terminal message.
PeriodicPurge2 5010 None
Collection event when a periodical purging of the needle for Valve 2 has
been performed.