Owner's manual
Table B-1 Collection Events (Continued)
B-12 Appendix B - Collection Events
Collection Event Name CEID
Related
Data Variables
Description
ce_ValidationAbort 3805 None Not used
ce_PurgePass_V2 3806 None Collection event when purge on valve 2 is completed successfully.
ce_PurgeFail_V2 3807 None Collection event when purge on valve 2 fails.
PromptedSetupStarted 4001 573
Collection event when scripted prompted setup has started either
manually by the operator or remotely from a SECS/GEM host.
PromptedSetupCompleted 4002 573 Collection event when the Prompted Setup Process is completed.
FindNeedleXYZ (CE name incorrect)
FindNeedle (gcd file name for 4003)
4003 None Collection event when a needle XYZ calibration has been performed.
ManualMeasureFlowRate1 4004 None
Collection event when a flow rate measurement for Valve 1 has been
initiated by an operator.
ManualPurgeNeedle1 4005 None
Collection event when a needle purging of Valve 1 has been initiated by
an operator.
OperationLevelChanged 4006 None
Collection event when the system operation level has been changed
from the dialog.
PasswordsModified 4007 None
Collection event when the system operation level passwords have been
modified.
ManualMeasureFlowRate2 4008 None
Collection event when a flow rate measurement for Valve 2 has been
initiated by an operator.
ManualPurgeNeedle2 4009 None
Collection event when a needle purging of Valve 2 has been initiated by
an operator.
ScaleRead1 4010 406
Collection event when the Scale has been read after Valve 1 has
dispensed material during the Dispense Weight Verification Procedure.
Data Variable ScaleMeasurement1 holds the scale measurement.
ScaleRead2 4011 407
Collection event when the Scale has been read after Valve 2 has
dispensed material during the Dispense Weight Verification Procedure.
Data Variable ScaleMeasurement2 holds the scale measurement.
FlowRate1Updated 4012 400
Collection event when the Flow Rate for Valve 1 has been updated
(Data Variable FlowRate1 has been modified).