Owner's manual

Table B-1 Collection Events (Continued)
Appendix B - Collection Events B-3
Collection Event Name CEID
Related
Data Variables
Description
GemEquipmentOFFLINE 22 None Collection event when Control State changes to Off-Line.
GemSpoolingActivated 23 None
Collection event when Equipment attempts to send a primary message
to the Host and gets a transmit failure while Spooling is enabled.
GemSpoolingDeactivated 24 None Collection event after the entire spool file has been read by the Host.
GemSpoolTransmitFailure 25 None
Collection event if a transmission failure occurs during the period in
which the Host is reading the Spooling file.
BoardAtDispenseLoc1 2001 521, 571
Collection event when the board is at the dispensing location for
Conveyor 1 and ready for dispensing.
DispensingDone1 2002 521
Collection event when dispensing is completed for Conveyor 1. The
board is ready to leave the dispensing location.
BoardAtDispenseLoc2 2003 521, 572
Collection event when the board is at the dispensing location for
Conveyor 2 and ready for dispensing.
DispensingDone2 2004 521
Collection event when dispensing is completed for Conveyor 2. The
board is ready to leave the dispensing location.
BoardFrequencyDataUpload 2010 106
Collection event per boat count during a production run. The boat count
is specified by equipment constant 610.
BarcodeRead 2050 306, 307
Collection event after a barcode has been successfully read. This event
will occur after events BoardAtDispenseLoc1 and
BoardAtDispenseLoc2.
MachineEmpty 2051 None
Collection event when the machine has set idle waiting for a board after
a user configurable timeout.
NewProgramLoaded 3001 461 Collection event when a new program is loaded.
NewFluidFileLoaded1 3002 SV300 Collection event when a new fluid parameter file for Valve 1 is loaded.
NewHeaterFileLoaded 3003 458 Collection event when a new heater parameter file is loaded.
FluidParametersModified1 3004 SV 300
Collection event when the fluid parameters for Valve 1 have been
changed by an operator.
FluidParametersSaved1 3005 SV 300
Collection event when the fluid parameters for Valve 1 have been saved
onto the local mass storage.