Owner's manual

Table A-1 All Variables (Continued)
A-64 Appendix A - All Variables
Variable Name
Data Type
ID
SECS Type
Related
Collection
Events
Description
h_HighProcAlarmSetPoint DV 11443 A[30] 3653 Heater high process alarm set point
h_HighProcAlarmMode DV 11444 I4 3654 Heater high process alarm mode
h_LowProcAlarmOutput DV 11445 I4 3654 Heater low process alarm output
h_LowProcAlarmSetPoint DV 11446 A[30] 3653 Heater low process alarm set point
h_LowProcAlarmMode DV 11447 I4 3654 Heater low process alarm mode
h_HighDevOutput DV 11448 I4 3654 Heater high device output
h_HighDevMode DV 11449 I4 3654 Heater high device mode
h_LowDevOutput DV 11450 I4 3654 Heater low device output
h_LowDevMode DV 11451 I4 3654 Heater low device mode
h_LocalMachineHeaterOffset DV 11452 I4 3654 Heater local machine offset
LastHeaterFileParm DV 11599 I2 3654 Last heater file parameter
p_version DV 11600 A[30] 3672 First program header VID
p_units DV 11601 A[30] 3672 User units
p_fluid1Filename DV 11602 A[100] 3672 Fluid filename #1
p_fluid2Filename DV 11603 A[100] 3672 Fluid filename #2
p_heater1Filename DV 11604 A[100] 3672 Heater filename #1
p_heater2Filename DV 11605 A[100] 3672 Heater filename #2
p_heater3Filename DV 11606 A[100] 3672 Heater filename #3
p_heater4Filename DV 11607 A[100] 3672 Heater filename #4
p_AttachFluidFile DV 11608 A[4] 3672 Is fluid file attached
p_AttachHeaterFile DV 11609 A[4] 3672 Is heater file attached
p_MovetoFirstFidLocation DV 11610 A[4] 3672 Move to first fid location
p_MoveToSystemLocation DV 11611 A[4] 3672 Move to system location
p_SystemLocationName DV 11612 A[100] 3672 System location name