Owner's manual

Table A-1 All Variables (Continued)
A-16 Appendix A - All Variables
Variable Name
Data Type
ID
SECS Type
Related
Collection
Events
Description
DWVMeasuredRange DV 415 F8 4020
This is the dispense weight verification measured range. If
range limit checking is enabled, this variable will be
compared against DMVTARGETRANGE and used as one
of the conditions for a pass/fail result. If limit checking is
not enabled, this value will still be valid but not used in the
pass/fail decision.
If the routine fails to due limit checking or is interrupted
before it completes, the variable will contain “-1”.
Valid only after collection event
“DispenseWeightComplete” occurs.
DWVMeasuredAvg DV 416 F8 4020
Dispense Weight Verification Average: average weight of
all dispenses after the dispense weight verification
completes or “-1” if the routine fails or is interrupted before
it completes.
Valid only after collection event
“DispenseWeightComplete” occurs.
DWVValveOnTime DV 417 F8 4020 Dispense Weight Verification valve on time
RefillRate1 DV 418 A[40] 3672 DP refill rate for valve 1
RefillRate2 DV 419 A[100] 3672 DP refill rate for valve 2
CPJCheckResultStatus DV 420 U2
3701
3702
CPJ check result status bytes
ValvePressure_V1 SV 421 F8 3703 Valve pressure on valve 1
FluidPressure_V1 SV 422 F8 3704 Fluid pressure on valve 1
CoolingPressure_V1 SV 423 F8 3705 Cooling pressure on valve 1
ValvePressure_V2 SV 424 F8 3706 Valve pressure on valve 2
FluidPressure_V2 SV 425 F8 3707 Valve pressure on valve 2