Owner's manual
Table A-1 All Variables (Continued)
A-14 Appendix A - All Variables
Variable Name
Data Type
ID
SECS Type
Related
Collection
Events
Description
FlowRateMax2 DV 405 F8 4013
The maximum flow rate for Valve 2 in mg./sec. allowed
during this run.
ScaleMeasurement1 DV 406 F8 4010
The actual value read from the scale during a Dispense
Weight Verification Procedure when Valve 1 is being
used.
ScaleMeasurement2 DV 407 F8 4011
The actual value read from the scale during a Dispense
Weight Verification Procedure when Valve 2 is being
used.
DWVResult DV 408 U2 4020
Result of Dispense Weight Verification Routine:
0 = Pass
1 = Fail: Setup error (scale not ready, limits out of
range, etc.)
2 = Fail: Out of Range
3 = Fail: Weight measured below min deviation
4 = Fail: Weight measured above max deviation
5 = Fail: User abort
6 = Fail: Other reason than listed above
DWVValve DV 409 U2 4020
Valve used during Dispense Weight Verification:
1 = Valve 1
2 = Valve 2
3 = Valve 3
Valid only after collection event
“DispenseWeightComplete” occurs.
DWVTarget DV 410 F8 4020
Dispense Weight Verification target weight.
Valid only after collection event
“DispenseWeightComplete” occurs.