Owner's manual
Table A-1 All Variables (Continued)
Appendix A - All Variables A-13
Variable Name
Data Type
ID
SECS Type
Related
Collection
Events
Description
FluidState1 DV 306 A[10] 2001
Fluid level of syringe on Valve 1as reported by the low
fluid sensor or fluid level monitoring software. This value is
updated twice per board. Once when the board is loaded
and ready for dispensing and again when dispensing is
complete on that board. Possible values are:
“FULL” – Fluid level is full.
“LOW” – Fluid level has reached the low level.
“EMPTY” – Fluid level is close to empty. This value is
possible only with the two position hardware sensor.
“NONE” – Fluid sensing sensors do not exist or
software monitoring has not been turned on.
“ERROR” – Error when using the two position
hardware sensor. Signals indicate empty but not low.
FluidState2 DV 307 A[10] 2003 Same as FluidState1 but for Valve 2.
OperatorLoginID SV 340 A[100] None Operator login ID
BarcodeRaw DV 350 A[30] 2050
The barcode string exactly as it is read by the scanner
from the barcode tag on the board at the dispense station.
BarcodeFiltered DV 351 A[30] 2050
The barcode string read in from the scanner after
unwanted characters are filtered out as specified by the
Operator.
FlowRate1 DV 400 F8 4012 The most current fluid flow rate for Valve 1 in mg./sec.
FlowRateMin1 DV 401 F8 4012
The minimum flow rate for Valve 1 in mg./sec. allowed
during this run.
FlowRateMax1 DV 402 F8 4012
The maximum flow rate for Valve 1 in mg./sec. allowed
during this run.
FlowRate2 DV 403 F8 4013 The most current fluid flow rate for Valve 2 in mg/sec.
FlowRateMin2 DV 404 F8 4013
The minimum flow rate for Valve 2 in mg./sec. allowed
during this run.