Owner's manual

Table A-1 All Variables (Continued)
Appendix A - All Variables A-11
Variable Name
Data Type
ID
SECS Type
Related
Collection
Events
Description
NumFailedBoards DV 107 U4
9000
9001
The number of boards failed during this run.
GCP_BuildVersion SV 108 U4 None GCP file build number
RunMode SV 110 U1 None
The various types of run operations:
0 = Standby
1 = Production Dry
2 = Production Wet
3 = Pass-through
4 = Lane 1 Continuous/Lane 2 Pass-through
5 = Lane 1 Pass-through /Lane 2 Continuous
6 = Manual Wet
7 = Manual Dry
8 = Not Ready
9 = Invalid
VisionFailures EC 112 U4 None
The count of vision system failures counted by the
Fluidmove software since the Power On event or since the
last change of Process Programs. The Host may clear this
variable to measure failures during a run.
BoardCycleTime DV 114 U2
2002
2004
The time in seconds needed to complete dispensing a
board.
DeviceID SV 115 A[12] None The SECS Device ID.
FluidFileName1 SV 300 A[40] None
This is the name of the file containing the dispensing fluid
data for Valve1. The file extension is “.flu”. The DOS 8.3
file name format is used. There are up to eight characters
reserved for the name and up to three characters for the
extension. The name and extension are thus separated by
a period: “name.ext”. The file name is left justified within
the character string, and spaces pack any remaining
space to the right of the file name.