Owner's manual
Table A-1 All Variables (Continued)
A-10 Appendix A - All Variables
Variable Name
Data Type
ID
SECS Type
Related
Collection
Events
Description
WBitS6F1 EC 85 U1 None Gem WBIT S6F1
SoftwareID SV 101 A[20] None
The Fluidmove software name and version code. The
version is in Major and minor format with a period
separating the parts. Up to seven letters in an
alphanumeric suffix follow the capitol A and hyphen in the
name as shown. Spaces pack any remaining space to the
right of the software ID.
MachineID SV 102 A[30] None
The machines Model number and Serial number. The
MachineID format is: “Model SNXXXXX “. The Model
field is fixed at twenty characters. The Serial Number field
is fixed at ten characters and contains up to five
characters in the serial number. Spaces pack any
remaining space to the right of both fields.
PPDirectory SV 103 A[30] None
The directory path holding the Process Programs. The
format is: “vol:\dir1[\dir2[\dir3]]”. Brackets indicate optional
directory levels. The volume indicator is a single letter.
EventLogFilename SV 104 A[12] None The name of the file holding the event records log.
ProductionStartTime SV 105 A[14] None
The time stamp when production started. The format is:
YYYYMMDDhhmmss. Similar to the TIME(39) variable
format.
YYYY = year from 0000 to 9999
MM = month from 01 to 12
DD = day from 01 to 31
hh = hours from 00 to 59
mm = minutes from 00 to 59
ss = seconds from 00 to 59
BoardCount SV 106 U4 None
The number of boards processed since the Power On
event or since the last Process entry into the Running
state.