Variable Name
Data Type
ID
SECS Type
Related
Collection
Events
Description
PPChangeStatus DV 41 U1 (GEM)
The action (create, change, delete) taken on a Process
Program.
1 = Created
2 = Changed
3 = Deleted
OfflineSubstate EC 42 U1 None
The default (power-up) offline substate of the Control
State Model.
1 = Equipment Off-Line
2 = Attempt On-Line
3 = Host Off-Line
OnlineFailed EC 43 U1 None
The default Control State transition when Attempt On-Line
fails.
1 = Equipment Off-Line
2 = Host Off-Line
OnlineSubstate EC 44 U1 None
The default (power-up) online substate of the Control
State Model.
4 = Local
5 = Remote
MaxSpoolTransmit EC 46 U4 None
The maximum number of spooled messages the
equipment will send each time the Host reads the spool. A
setting of zero indicates that all spooled messages should
be sent. Refer to the description of S6F23 in the "SECS
Message Detail" section for further information.
SpoolCountActual SV 48 U4 None
A count of the number of messages actually present on
the spool disk, adjusted for any messages which have
been overwritten or otherwise discarded.