Table A-1 All Variables (Continued)
A-4 Appendix A - All Variables
Variable Name
Data Type
ID
SECS Type
Related
Collection
Events
Description
AlarmsSet SV 24 L None
A list of all Alarms which are currently in the SET (on)
state. Format as follows:
<L
1.<U4 ALID>
...
n.<U4 ALID>
>
AlarmState SV 25 U1 None
The Alarm State now in effect for the most recently
transitioned alarm.
0 = Alarm transitioned OFF
1 = Alarm transitioned ON
AlarmSerial SV 26 U4 None
The sequence number of the most recent alarm change
(going on or going off). This number starts at zero at
power-up and increments by one for each alarm transition
which occurs.
Clock SV 27 A None
The Equipment's current Date and Time in the following
format: YYYYMMDDhhmmsscc.
YYYY = year from 0000 to 9999
MM = month from 01 to 12
DD = day from 01 to 31
hh = hours from 00 to 59
mm = minutes from 00 to 59
ss = seconds from 00 to 59
cc = centiseconds from 00 to 99