Table A-1 All Variables (Continued)
Appendix A - All Variables A-3
Variable Name
Data Type
ID
SECS Type
Related
Collection
Events
Description
RpType EC 17 Boolean None
This EC controls some aspects of the format of Event
Reports sent by this Equipment.
FALSE = Normal Event Reports
TRUE = Annotated Event Reports
WBitS10 EC 18 U1 None
An EC which controls the W-Bit setting used when
sending S10F1.
0 = W-Bit not set
1 = W-Bit set
WBitS5 EC 19 U1 None
An EC which controls the W-Bit setting used when
sending Alarm Reports (S5F1, S5F71, or S5F73).
0 = W-Bit not set
1 = W-Bit set
WBitS6 EC 20 U1 None
An EC which controls the W-Bit setting used when
sending stream six messages (events, trace)
0 = W-Bit not set
1 = W-Bit set
AbortLevel SV 21 U1 None The AbortLevel of the most recent ABORT command.
AlarmID DV 22 U1 None The ALID of the most recent Alarm transition.
AlarmsEnabled SV 23 L None
A list of all Alarms which are currently enabled. Format as
follows:
<L,n
1.<U4 ALID>
...
n.<U4 ALID>
>