Owner's manual
Machine Variable Definitions 6-3
Table 6-1 Status Variables (continued)
Variable Name ID
Storage
Type
Description
PREVIOUSPROCESSSTATE 36 U1
The previous Process State for the Equipment. The
values for this state can be found in Appendix A.
PROCESSSTATE 37 U1
The current Process State for the Equipment. The
values for this state can be found in Appendix A.
ProductionStartTime 105 A[14]
The time stamp at which the last production run
began. Refer to Appendix A for the format.
RunMode 110 U1
The specific type of runtime operation being
conducted; dry run, production run, pass-through,
or prototype test run.
SOFTREV 38 A[6] The software revision number in ASCII code.
SoftwareID 101 A[20] Fluidmove name and version code.
SPOOLCOUNTACTUAL 48 U4
A count of the number of messages actually
present on the spool disk, adjusted for any
messages which have been overwritten or
discarded.
SPOOLCOUNTTOTAL 49 U4
A count of the number of messages the Equipment
attempted to write to the spool disk. This number
includes messages actually present on the spool
disk, and any messages which may have been
overwritten or discarded.
SPOOLFULLTIME 50 A[16]
The date and time at which the Spool file became
full. The format is : YYYYMMDDhhmmsscc.
SPOOLLOADSUBSTATE 51 U4
The current state within the SPOOL LOAD super-
state.
1 - Spool Active
2 - Spool Inactive
SPOOLSTARTTIME 52 A[16] See CLOCK variable above for this format.
SPOOLSTATE 53 U4
The current Spool State within the POWER ON
super-state.
3 - Purge Spool
4 - Transmit Spool
5 - No Spool output
SPOOLUNLOADSUBSTATE 54 U4
The current Spool State within the
SPOOLUNLOAD super-state.
6 - Spool not full
7 - Spool full
TIME 39 A[12]
The current time accurate to the second. The
format is YYMMDDhhmmss. This format is always
the same, regardless of TIMEFORMAT.