Owner's manual
SECS Scenarios 5-3
5.2 Data Collection
5.2.1 Host Initializes Event Reporting
Table 5-6 SECS Messages Host Initializes Event Reporting
Step SECS Message Description
1 H -> E S2F37 W
Disable Event Reports. The Host disables reporting for all
Collection Events.
S2F37 W
<L [2]
<BOOLEAN F>
<L>
> .
2 H <- E S2F38
The Equipment acknowledges. Temporarily, the Equipment will
make no event reports.
3 H ->E S2F33 W
Define Report. The Host erases all previous report definitions
and links:
S2F33 W
<L [2]
<U4 DATAID>
<L>
> .
4 H <- E S2F34 The Equipment acknowledges.
5 H -> E S2F33 W Define Report. The Host sends report definitions.
6 H <-E S2F34 The Equipment acknowledges.
7 H -> E S2F35 W
Link Events/Reports. The Host links reports to the desired
Collection Events. Linked Reports are initially “disabled”.
8 H <- E S2F36 The Equipment acknowledges.
9 H -> E S2F15 W
Equipment constant “Send”. The Host sets equipment constant
“RpType” to indicate whether event reports should be in
“Normal” or “Annotated” format.
10 H <- E S2F16 The Equipment acknowledges.
11 H -> E S2F37 W
Enable event reports. The Host enables reporting for desired
collection events.
12 H <- E S2F38
The Equipment acknowledges. From this point on, the
Equipment will report events as they occur.