4-40 SECS Message Detail
4.2.61 S6F2 - Trace Data Acknowledge
S6F2 * H->E
<B [1] 00> . * ACKC6
The Host acknowledges the data. The Equipment ignores ACKC6.
4.2.62 S6F3 - Annotated Event Report
S6F3 [W] * H<-E, Multiblock
<L [3]
<U4 DATAID> * DATAID
<U4 CEID> * Collection Event ID
<L
<L [2]
<U4 DSID> * DSID=RPTID Report ID
<L
<U4 VID> * Variable ID
<V> * Variable Value
>
...
>
>
...
>
> .
NOTE This message is provided only for compatibility with older Host computers which do
not support GEM (refer to 1.9.3 GEM Configuration).
If the equipment constant “ConfigEvents” is set to “0”, the Equipment sends S6F3 instead of the normal
S6F13 Annotated Event Report.
A Collection Event has occurred at the Equipment. The Host has enabled Event Reporting for this CEID
(refer to 4.2.36 S2F37 - Enable/Disable Event Report). The Host has set the Equipment constant RpType
to “True” (Annotated report format desired). The Equipment sends one or more Event Reports which the
Host has previously linked to that CEID (refer to 4.2.35 S2F36 - Link Event Report Acknowledge). Each
report contains specific Variables which the Host has previously defined for that Report (See 4.2.32
S2F33 - Define Report).
The Equipment generates a value for DATAID to uniquely identify this Conversation. If S6F3 is
multiblock, the Equipment first sends the S6F5/S6F6 Inquire/Grant transaction, and DATAID in S6F3
will match DATAID in S6F5.