Owner's manual

SECS Message Detail 4-37
4.2.56 S5F71 - Alarm Report Block Send
S5F71 [W] * H<-E
<L [2]
<U1 0> * ALPY Alarm Priority
<L [1]
<L [4]
<U4 ALID> * ALID - Alarm ID
<BOOLEAN ASTAT> * T = Alarm On, F = Alarm Off
<U4 ASER> * ASER Alarm Serial Number
<A [16] YYYYMMDDhhmmsscc > * CLOCK
>
>
> .
NOTE This message is provided only for compatibility with Host computers which support an
older version of GEM.
If the equipment constant “ConfigAlarms” is set to “1”, the Equipment sends S5F71 instead of the
normal S5F1 Alarm Notification Send.
The Equipment reports that an alarm condition has changed.
ALID identifies the Alarm.
ASTAT value is “True” (Non-zero) if this alarm is currently On (Unsafe), or “False” (Zero) if it is
currently Off (Safe).
ASER (Alarm Serial Number) is assigned by the Equipment. Its value begins at “1” and is incremented
by 1 for each alarm reported.
ALPY (Alarm Priority) is always zero.
CLOCK indicates the date and time of the alarm change.
Equipment constant “Wbits5” controls whether the Equipment sends S5F71 with W-bit “1” (Reply
Expected) or “0” (No Reply Expected).