Owner's manual
4-24 SECS Message Detail
4.2.41 S2F42 - Remote Command Acknowledge
S2F42 * H<-E
<L [2]
<B [1] HCACK> * Host Command Ack. Code
<L [n]
<L [2]
<A CPNAME> * Name of Parameter
<B [1] CPACK> * Cmd Param Ack Code
>
...
>
> .
Normal completion returns a zero (0) in HCACK. The number of erroneous parameters “N” in S2F42
will be zero.
A non-zero value for HCACK indicates that the Equipment has rejected the Remote Command. The
number of erroneous parameters “n” can be zero or greater.
Table 4-12 HCACK Values
HCACK Description
0x00 OK. All normal.
0x01 Invalid command. Equipment rejects command.
0x02
Cannot perform now. Equipment rejects command.
Fluidmove is not in Run Window screen.
0x03
At least one parameter is invalid. Equipment rejects
the command.
0x40 Control State is Local. Equipment rejects command.
0x41
Incorrect Process State for this command. Equipment
rejects command.
0x42
Process Program contains an invalid format. Unable to
load program.
NOTE Fluidmove is currently not returning the HCACK rejection codes (upon successful
completion HCACK will still be returned as zero). To indicate command rejection, the
RCMD string will be echoed back to the Host with no HCACK value.