Manual

Introduction 1-21
Item Name Description
1
Establish
Communication
Timeout
The user-configurable equipment constant that defines the delay, in seconds,
between attempts to send S1F13. This value is used to initialize the CommDelay
timer.
2
Default
Communication
State
Allows the user define the default communication state upon Fluidmove’s startup.
The valid choices are:
ENABLED:
Fluidmove will attempt to establish communication link upon start up.
DISABLED:
Fluidmove will not attempt to establish communication link upon
startup.
Recommended: ENABLED
3
Default Control
State
Allows the user define the default control state upon Fluidmove’s startup. The valid
choices are:
OFFLINE/ATTEMPT ONLINE, OFFLINE/EQUIPMENT OFFLINE, OFFLINE/HOST
OFFLINE, ONLINE/LOCAL, ONLINE/REMOTE
Refer to 5.4 Control State for descriptions.
Recommended: ONLINE/REMOTE
4
If On-line
Attempt Fails
Go To
Allows the user to select what to do if attempting to go on-line fails for any reason.
The valid choices are:
OFFLINE/HOST OFFLINE, OFFLINE/EQUIPMENT OFFLINE
Refer to 5.4 Control State for descriptions.
Recommended: OFFLINE/HOST OFFLINE
5
Beep Until
Incoming
Message
Acknowledged
If selected, Fluidmove will beep twice a second to notify the user of arrival an
incoming terminal message from the Host. The GEM status bar blinks at the same
rate to catch user’s attention regardless of this option being selected or not. The
user should then go to the Terminal tab to view and acknowledge the message.
6 Status Box Displays the current communication state, control state, and spooling state.
Figure 1-4 SECS/GEM Setup Dialog Box – Setup Tab (FmXP shown)
2
3
1
6
4
5