Manual

Appendix D – New Variables D-5
Finally, “(none)” will be returned by the equipment for those integer, floats or arrays which have no value. For instance, light states, defined as A[30],
may contain four integer values “INT,INT,INT,INT” but if the light state has not been defined the equipment will return a single string “(none)”.
Table D-4 lists the configuration variables.
Table D-4 Configuration Variables
Variable Name
ID SECS
Type
Storage Type FmConfig.ini Entry
Misc Parms
c_MachineSetupMode 6000 A[20] ASCII Machine Setup Mode =
c_ScriptedVOFileName 6001 A[60] ASCII Scripted VO File Name =
c_CameraAssistedScripts 6002 A[4] ASCII Camera Assited Scripts =
c_EnableFindTeachXYZ 6003 A[4] ASCII Enable Find/Teach XYZ =
c_CheckLocalRecipeFiles 6004 A[4] ASCII Check Local Recipe Files =
c_ChangeOperationLevel 6005 A[4] ASCII Change operation level when program idle =
GEM Manager
c_GemInstalled 6006 A[4] ASCII Gem Installed =
c_GemEnabled 6007 A[4] ASCII Gem Enabled =
c_DefaultCommState 6008 I4 INT Default Comm State =
c_DefaultControlState 6009 I4 INT Default Control State =
c_OnlineFailedState 6010 I4 INT Online Failed State =
Password
c_StartinProdOplevel 6011 A[4] ASCII Start in Prod operation level =
Heater Manager
c_PollInterval 6012 I4 INT Poll Interval =
c_DisableAfterRun 6013 A[4] ASCII Disable After Run =