Manual

Appendix D – New Variables D-1
Appendix D – New Variables
"NOTE This appendix applies to the FmNT 4.8.4 and FmNT 4.8.5 releases of Asymtek’s
FluidMove software only.
D.1 Setup Level Variables
lists the setup level variables.
Table D-1 Setup Level Variables
Variable Name Data
Type
ID Storage
Type
Description
c_ScaleLocationXYZ_V1 EC 6497 A[50] Scale XYZ location for valve 1
c_PurgeLocationXYZ_V1 EC 6498 A[50] Purge XYZ location for valve 1
c_NeedlePositionoverTactile_V1 EC 6328 A[40] Tactile Sensor XY location for valve 1
c_CurSafeZ EC 6225 F8 Safe Height Z
c_XYNeedleOffset_V1 EC 6295 A[40] Camera to needle XY offset for valve 1
c_ZNeedleOffset_V1 EC 6294 F8 Needle tip to height sense probe Z offset
for valve 1
D.2 Lot Level Variables
Table D-2 lists the lot level variables.
Table D-2 Lot Level Variables
Variable Name
Data
Type
ID Storage
Type
Related
Collection
Description
FlowRate1 DV 400 F8 4012 Flow rate for valve 1
ScaleMeasurement1 DV 406 F8 4010 Scale measurement for valve 1
DWVMEASUREDAVG DV 416 F8 4020 Average measured weight of all
dispenses during the dispense
weight verification procedure.
RefillRate1 DV 418 A[40] 3001 DP refill rate for valve 1
SPHTR1CHAN1-
SPHTR1CHAN17
DV 1101
to
1117
F8 3003 Set Points for Heater 1
channels 1 to 17.