Appendix A – Data Dictionary Variables A-9
Table A-1 Data Dictionary Variables (continued)
VID Class Format Name and Description
404 DV F8
FlowRateMin2
. The minimum flow rate for Valve 2 in mg./sec. allowed
during this run.
405 DV F8
FlowRateMax2
.The maximum flow rate for Valve 2 in mg./sec. allowed
during this run.
406 DV F8
ScaleMeasurement1
. The actual value read from the scale during a
Dispense Weight Verification Procedure when Valve 1 is being used.
407 DV F8
ScaleMeasurement2
. The actual value read from the scale during a
Dispense Weight Verification Procedure when Valve 2 is being used.
408 DV U2
DWVRESULT
. Result of Dispense Weight Verification Routine:
0 = Pass
1 = Fail: Setup error (scale not ready, limits out of range, etc.)
2 = Fail: Out of Range
3 = Fail: Weight measured below min deviation
4 = Fail: Weight measured above max deviation
5 = Fail: User abort
6 = Fail: Other reason than listed above
409 DV U2
DWVVALVE
. Valve used during Dispense Weight Verification:
1 = Valve 1
2 = Valve 2
3 = Valve 3
Valid only after collection event “DispenseWeightComplete” occurs.
410 DV F8
DWVTARGET
. Dispense Weight Verification target weight.
Valid only after collection event “DispenseWeightComplete” occurs.
411 DV U4
DWVDISPENSES.
Dispense Weight Verification: number of dispenses
that will be performed.
Valid only after collection event “DispenseWeightComplete” occurs.
412 DV F8
DWVTARGETRANGE
. Dispense Weight Verification Target Range: If
range limit checking is enabled, this variable will contain the maximum
allowable range for the dispense weight verification routine. If limit
checking is not enabled, this variable will contain “-1”.
Valid only after collection event “DispenseWeightComplete” occurs.
413 DV F8
DWVTARGETMINLIMIT
. Minimum allowable deviation from the target
weight of the dispense weight for the Dispense Weight Verification
routine.
Note: If the verification routine fails and the failed weight is required, the
data variable “SCALEMEASUREMENT1” (if valve 1) or
“SCALEMEASUREMENT2” (if valve 2) will have the last value read from
the scale.
Valid only after collection event “DispenseWeightComplete” occurs.