Manual
6.2 Data Variables
Table 6-2 Data Variables
Variable Name ID Storage
Type
Description
ALARMTEXT 1000 A[0..40] The Alarm Text ( ALTX ) for the most recent alarm
transition.
ALARMSEVERITYCODE
1001 B[1] The Severity Code (the low order seven bits) of the
most recent alarm transition.
BarcodeRaw 350 A[30] The barcode string exactly as it is read by the scanner
from the barcode tag on the board at the dispense
station.
BarcodeFiltered 351 A[30] The barcode string read in from the scanner after
unwanted characters are filtered out as specified by the
Operator.
BoardCycleTime 114 U2 The number of seconds required to complete
dispensing an entire board of substrates.
ConveyorSpeed1 500 F4 The Conveyor 1 belt speed during board transfer
between dispensing positions. The units are in./sec.
ConveyorSpeed2 501 F4 The Conveyor 2 belt speed during board transfer
between dispensing positions. The units are in./sec.
DWVRESULT 408 U2 Result of Dispense Weight Verification Routine:
0 = Pass
1 = Fail: Setup error (scale not ready, limits out of
range, etc.)
2 = Fail: Out of Range
3 = Fail: Weight measured below min deviation
4 = Fail: Weight measured above max deviation
5 = Fail: User abort
6 = Fail: Other reason than listed above
DWVVALVE 409 U2 Valve used during Dispense Weight Verification:
1 = Valve 1
2 = Valve 2
3 = Valve 3
Valid only after collection event
“DispenseWeightComplete” occurs.
DWVTARGET 410 F8 Dispense Weight Verification target weight.
Valid only after collection event
“DispenseWeightComplete” occurs.
6-4 Machine Variable Definitions