6. Machine Variable Definitions
The following data variables are collected by the Host to support intelligent communications with
the Equipment:
Status Variables
Data Variables
Equipment Constants
Each variable is given a header line with its associated ID value and its name. The storage type and the
definition of the variable are listed below in smaller type. Variables listed in the header in capital letters
are GEM standards. The others belong to FmNT.
All variables are listed in alphabetical order.
6.1 Status Variables
Table 6-1 Status Variables
Variable Name ID Storage
Type
Description
ABORTLEVEL 21 U1 The abort level of the most recent ABORT command.
ALARMID 22 U4 This variable contains the ID of the last alarm to be
reported to the Host.
ALARMSENABLED 23 List This variable contains the list of the currently enabled
alarms. Refer to Appendix A for the format.
ALARMSERIAL 26 U4 The sequence number (count) of the most recent
alarm change( going on or going off). This number
starts at zero at power-up and increments by one for
each following alarm transition.
ALARMSSET 24 List This variable contains the list of alarms which are
currently set.
ALARMSTATE 25 U1 The state of the current alarm. Non zero values
indicate the alarm is set.
BoardCount 106 U4 The number of boards processed since the Power On
event or since the last Process entry into the Running
state.
CameraXFieldMils 700 U2 The size in mils of the X coordinate axis field of view
seen by the camera.
CameraYFieldMils 701 U2 The size in mils of the Y coordinate axis field of view
seen by the camera.