Owner's manual

Table Of Contents
4.2.67 S6F10 - Event Report Acknowledge
S6F10 * H->E
<B [1] 00> . * ACKC6
The Host acknowledges the Event Report. The Equipment ignores ACKC6.
4.2.68 S6F11 - Event Report Send
S6F11 W * H<-E
<L [3]
<U4 DATAID> * DATAID
<U4 CEID> * Collection Event ID
<L
<L [2]
<U4 RPTID> * Report ID
<L
<V> * Variable Value
...
>
>
...
>
> .
This message is the “normal” message that the Equipment uses to report events. In order for this message
to be used, the equipment constant “ConfigEvents” must be set to “1”.
An Event Report will be sent if a Collection Event has occurred at the Equipment. The Host has enabled
Event Reporting for this CEID (refer to 4.2.36 “S2F37 – Enable/Disable Event Report”). The Host has
set the equipment constant “RpType” to “False” (normal report format desired). The Equipment sends
one or more Event Reports which the Host has previously linked to that CEID (refer to 4.2.34 “S2F35 –
Link Event Report”). Each report contains specific Variables which the Host has previously defined for
that Report (refer to 4.2.32 “S2F33 – Define Report”).
The Equipment generates a value for DATAID to uniquely identify this Conversation. If S6F11 is
multiblock, the Equipment first sends the S6F5/S6F6 Inquire/Grant transaction, and the DATAID in
S6F11 will match DATAID in S6F5.
If the CEID is enabled, but no Reports are linked to this CEID, S6F11 has the following special format:
S6F11 W * H<-E
<L [3]
<U4 DATAID> * DATAID
<U4 CEID> * Collection Event ID
<L>
> .
4-46 Equipment-to-Host Messages