Owner's manual

4-34 System Configuration and Setup
4.3.10.4 E10 Equipment States
E10 Equipment States provides a quick summary of the overall performance and utilization of the
dispensing system that can be recorded in the machine log file.
4.3.10.4.1 Equipment States and Substates
This feature tracks the amount of time the dispensing system is in the six basic activity states defined by
SEMI specifications E10 and E58. These states are described in Table 4-5.
Table 4-5 E10 Equipment States
Description Abbreviation State Code Color
Productive PRD 1000 Green
Standby SBY 2000 Yellow
Engineering ENG 3000 Blue
Scheduled Downtime SDT 4000 Light Red/Pink
Unscheduled Downtime UDT 5000 Red
Non-Scheduled Time NST 6000 Dark Gray
By default, FmXP does not use substates other than the “default” codes listed above. However, the
customer can customize the initialization (.ini) file and manually enter substates if desired.
4.3.10.4.2 E10 State Status Bar
When E10 Equipment States is enabled, an information status bar (Figure 4-34) appears at the bottom of
the screen just above the standard status bar. If SECS/GEM is enabled, E10 information is on the same
status bar with SECS/GEM information.
Equipment State: NST
Figure 4-34 E10 State Status Bar
The status bar indicates the current equipment state at all times using the abbreviations and color codes
listed above. A lock symbol is displayed when the operator has locked the current state. Access to the E10
setup property sheet is possible by double clicking on the E10 information section of the status bar. This
provides the ability to view statistics or to manually change or lock a state at any time.