Owner's manual

System Configuration and Setup 4-33
8. The selected air pressure is now calibrated.
Set Point = Actual Air Pressure present at the dispenser bulkhead fitting.
PSI Reading Pane (E/P Reg.) = Actual Air Pressure present at the dispenser bulkhead.
9. Click
OK when done.
10. Remove the pressure gauge from the dispenser bulkhead.
To Establish LMO Maintenance
1. Click on the
Maintenance tab.
Figure 4-33 Local Machine Offsets – Maintenance Tab
2. Click on the Enable box to enter the number of days for the period Warning and Failure
prompts to occur for each of the LMO items.
When the warn date has been reached, FmXP prompts the user that the LMO needs to
be reviewed. The LMO is still available for use.
On the fail date, FmXP prompts the user that the specific LMO has expired and is no
longer available for use. The LMO must be re-established.
3. Click
OK when done.