Owner's manual
4-18 System Configuration and Setup
4.3.9 Setup Scripts Options
Setup Scripts Options allows you to select or change the script file(s) FmXP executes when conducting
scripted machine setup procedures. It also allows you to add/delete scripted setup routines on the Setup
List in the Production Window. For detailed information about how script files are used, see 4.5 Machine
Setup and 4.6.2 Production Setup for M-2000, X-1000, S-900, S-800 and D-500 Series Systems.
NOTE If your dispensing system is equipped with a Dual Action Dispensing Head, you can
select the same script file or a different one for each valve.
To set up or change Prompted Setup, Change Syringe, or Low Fluid script files:
1. In the Main Window, select
Configuration > Setup Scripts Options.
The Setup Scripts Options window (Figure 4-13) opens.
2. Click on the
Prompted Setup, Change Syringe, or Low Fluid button as desired.
3. Choose a script file from the directory.
4. Click on
Open.
In the Setup Scripts Options Window, the name of the selected file appears in the text
box below the button.
5. Click on
OK.
To add or delete script files on the Production Setup List in the Production Window:
NOTE Production Setup List Configuration only allows you to add additional setup scripts to the
list and delete previously added scripts from the list. The other items on the list are hard-
coded in the software.
1. In the Main Window, select
Configuration > Setup Scripts Options.
The Setup Scripts Options window (Figure 4-13) opens.
2. Click on the
Production Setup List button.
The Production Setup List Configuration window (Figure 4-14) opens.
3. Perform one of the following as desired:
Click on
Add File. Select the script file you wish to add from the directory and click on
Open. The added file appears in the Script File list.
Click on the script file you wish to delete from the Setup List and click on
Delete File.
4. Click on
OK.
5. In the Setup Scripts Options Window, click on
OK.