System Configuration and Setup 4-17
Table 4-2 Machine Offsets Parameters Window
Command Description
Needle Sensor
Sensor Type
: Identifies the type of needle sensor installed or your system.
Sensor I/O Assignment
: Identifies the I/O assigned to the Needle Sensor
beams.
Tactile I/O Assignment
: Identifies the I/O assigned to the Tactile Sensor on
Model NSZ Series Needle Sensors.
Reverse Period
: Number of seconds between valve reversals during setup.
Reverse Time
: Number of seconds the valve is reversed each time.
Machine Offsets Mode
Scripted Valve Offsets
: On-screen prompted setup routine that can be
customized by selecting one of the pre-existing scripts, or by creating a new
script.
Valve Offsets
: This is an on-screen prompted setup routine that identifies
and records a Safe-Z height, the XYZ locations of the Purge and Weigh
Stations, locates the needle, finds the substrate height, and calibrates the
camera crosshair to known locations. This routine is performed when the
dispensing system is initially installed and configured. You should also
perform a Valve Offsets before production runs.
Calculate Master Offsets
: This routine performs the same function as Valve
Offsets. Calculate Master Offsets can only be performed on M-600 Series
Dispensing Systems equipped with a Needle Sensor.
Restore default setup locations
: Restores all "previously used" setup
locations for the selected method to their default values.
Machine Offsets
Parameters
Select Script File
: Lets you select a script (.pss) file to be used during the
scripted setup procedure.
Camera Assisted Script
: When this feature is ON, the camera is utilized
when calculating offsets during the scripted setup procedures. This
eliminates the need to enter the dispensing area to align needles or height
sensor probes with requested locations.
Setup Fiducials
: Select Setup Fiducials to teach fiducial locations for the
Fiducial Assisted Setup procedure. See 4.5.3.2 Setup.
Use Lookup Camera
– Available when the system is configured with a
lookup camera. Adds prompt windows to the offset routines that support
calibration of the valve lookup camera that is used for viewing the valve
nozzle.
Use Service Station Data
- Enables the Fiducial Setup for the dispense
service station. Permits the use of fiducials to automate the offset calibration
process.
4.3.8.2 Offset Routines
Selecting Scripted Valve Offsets, Valve Offsets, or Calculate Master Offsets from the Machine Offsets
menu runs the selected offset program. For more information, see 4.5 Machine Setup.