Owner's manual
A-12 Appendix A - Programming Menu Detail
18. Prime - Removes air from the pumping chamber. Activates a drop-down menu which allows you to
perform one of the following commands:
• DJ Series Fluid Priming (Vacuum Assisted)
- Uses an extra vacuum device to help prime a
valve.
• Post Prime Verification
- After priming, purges the valve until the valve start dispensing fluid.
A scale device is requested to verify the fluid dispensing has started.
• Prime with Timeout for DP Pumps
- This initiates the DP priming sequence for DP valves
only. Refill sequence starts after timeout.
19. DJ-9K - Dot Weight Pressure Setup
- Activates the pressure-controlled dot weight calibration
procedure for DJ valve types.
20. Needle Valve Speed - Flowrate Setup
- Activates the valve speed-controlled flowrate calibration
procedure for needle valve types.
21. Flux Flowrate - Pressure Setup
- Activates the pressure-controlled flowrate calibration procedure
for flux valve types.
22. Auto Tension
- Opens the Tensioner Setup dialog box in which you can setup and run the Auto
Tensioner feature. The Auto Tensioner is a pneumatic device employed to maintain proper tension
on the driver cables.
23. Read RFID Tags
- Moves the dispensing head through the RFID device location, reads the RFID
tags on the valve, and displays the content on the tags.
24. Fluid Agitation
- Starts, stops and levels the dispense fluid agitator. Requires optional fluid
agitation hardware.
25. Heater
- Activates Heater Control Windows.
26. Manual Board Load
- An operator-conducted function for loading a board by hand. Place the board
at the mouth of the Conveyor. Use the dispensing system Conveyor Controls to set the proper
width. Manual Board Load conveys the board into the dispensing area and clamps it into place.
27. Manual Board Unload
- Unclamps the board and conveys it to the end of the Conveyor for
manual unloading.
28. Download Conveyor Atom
- Downloads a specific set of instructions for controlling Conveyor 1 or
Conveyor 2.
29. Fluid Weights
- Active only if software tracking is enabled in Fluid Manager - Pot Life/Low Fluid
Check tab. Opens up a dialog box that displays Starting, Warning, and Critical weight settings as
well as the Current fluid weight.
30. System Variables
- This system variable allows a program to check the condition of one or two
inputs. The variable is "defined" as one or two inputs, the level of each input, and the logical
results of the two signals being AND’ed or OR’ed together. The results of this Boolean equation
can be tested for in the dispense program, either True or False.
31. Image Capture
- Displays a dialog to select which images to save to the "images" directory.