Owner's manual

Appendix A - Programming Menu Detail A-11
A.1.4 Setup Menu
1. Setup Scripts - Lets you select a specific setup script
for setup procedures.
2. Scripted Valve Offsets
- Launches the Scripted Valve
Offsets setup procedure.
3. Valve Offsets
- Launches the non-scripted Valve
Offsets setup procedure.
4. Find Needle XYZ
- Performs a Find Needle XYZ
Command, which takes you through a short setup
sequence for configuring needle XYZ parameters. This
feature is only available if either a full Offsets
Procedure has been already been performed or the
Teach Needle XYZ procedure has been performed.
5. Teach Needle XYZ
- Performs a Teach Needle XYZ
Command, which takes you through a short setup
sequence for defining the Needle Sensor beam
locations in relation to the dispensing needle.
6. Measure Flow Rate
- Performs a Flow Rate
Measurement, which measures the amount of fluid,
dispensed in a given amount of time. It allows you to
regulate flow rate to ensure fluid dispensing accuracy
and consistency.
7. Check CPJ Flowrate
- Activates the check dot weight
calibration procedure.
8. Dispense Weight Verification
- Opens a dialog box in which you can set up and run a dispense
weight verification.
9. Flux Weight Verification
- Opens a dialog box in which you can set up and run a flux weight
verification.
10. Purge Nozzle
- Activates the valve purge routine.
11. Purge Needle
- Performs a Purge Command.
12. Purge Needle Infinite
- Performs a Purge Needle Infinite command.
13. Vacuum On
- Turns on the Purge Station vacuum.
14. Vacuum Off
- Turns off the Purge Station vacuum.
15. Move To Center
- Moves the Dispensing Head to the center of the dispensing area.
16. Move To Front
- Moves the Dispensing Head to the front center of the dispensing area.
17. Valve
- Activates a drop-down menu which allows you to perform one of the following commands:
Forward/Reverse
- Turns valve ON to either forward or reverse.
Prime
- Purges air from the valve.
Refill
- Refills the DP-Series valve.
Identifier
- Allows the user to select the valve bias profile for the current valve.
Setup
Setup Scripts
Scripted Valve Offsets
Valve Offsets
Find Needle XYZ
Teach Needle XYZ
Measure Flow Rate
Check CPJ Flow Rate
Dispense Weight Verification
Flux Weight Verification
Purge Nozzle
Purge Needle
Purge Needle Infinite
Vacuum On
Vacuum Off
Move To Center
Move To Front
Valve
Prime
DJ9K Dot Weight Pressure Setup
Needle Valve Speed Flowrate Setup
Flux Flowrate Pressure Setup
Auto Tension
Read RFID Tags
Fluid Agitation
Heater
Manual Board Load
Manual Board Unload
Download Conveyor Atom
Fluid Weights
System Variables…
Image Capture