Owner's manual
Appendix A - Programming Menu Detail A-9
• Reset Multipass Timer - Allows you to reset a timer for a multipass pattern.
• Await Multipass Timer
- Allows you to establish wait time for a multipass pattern. Pauses the
program until the timer has elapsed before executing the next pass.
23. Motion
- Activates a drop-down menu for Motion Commands. Motion Commands are used to
move the needle/nozzle or camera during a program. Typically, Motion Commands are inserted
into the Main Dispensing Program rather than into a pattern.
• Move X,Y
- Moves to a defined location relative to the origin of the current pattern.
• Move Absolute X,Y
- Moves to a defined location relative to the machine’s origin.
• Move Absolute Z
- Moves to a defined Z-axis height.
• Goto System Location
- Moves to the Purge Station, Scale Station, or any other designated
location.
24. Send Commands
- Activates a drop-down menu from which you can select various Send
Command options.
• Send Dispenser
- Inserts a “Send to Dispenser “command into the currently loaded program.
• Send Conveyor
- Not available on systems with MPC555 (Axiom). Opens a dialog box for
inserting Conveyor ACL commands directly into a dispensing program. Inserts a "Send to
Conveyor" command into the currently loaded program.
• Send Conveyor 2
- Not available on systems with MPC555 (Axiom). Inserts a "Send to
Conveyor 2" command into the currently loaded program. This feature is only available on
systems configured with the dual Conveyor option.
25. Conveyor
• Send Board
- Inserts a “Send Board” command into your program.
• Use Conveyor 1 Block
- Available only on systems with dual conveyors. Inserts "Use
Conveyor 1" and "End Use Conveyor" commands into your program. If the Conveyor is
enabled and a board is present, the system performs the processes bracketed between them on
the part on Conveyor 1.
• Use Conveyor 2 Block
- Available only on systems with dual conveyors. Inserts "Use
Conveyor 2" and "End Use Conveyor" commands into your program. If the Conveyor is
enabled and a board is present, the system performs the processes bracketed between them on
the part on Conveyor 2.
• Block Upstream
- Stops the upstream machine from conveying a workpiece into the machine.
• Load from Downstream
- Request for a workpiece from the downstream machine. Typically
used for dispensing on top and bottom sides of the workpiece using a downstream inverter or is
used when a second pass of dispensing is required after the downstream machine has finished
its application. Afterwards, the upstream load direction is resumed.
• Index Board
- Moves workpiece to a 2nd dispensing location. This instruction is used for large
workpieces allowing Fluidmove the ability to index to a second clamping position on the
conveyor within a single dispense program. It will dispense on the first section of the
workpiece, index it to a second stop pin position and then dispense on the last section.