18. Enable/Disable Instruction - Instructions are used mainly for testing and troubleshooting during the
dispensing program development process. You can disable or enable a single line or multiple lines
within your dispensing program to isolate problems or to try different options.
To disable a command, use the mouse or trackball to highlight the line (or lines), and then click
on
Program>Instruction >Disable Instruction.
The disabled command(s) appears in red text within the dispensing program. When the
dispensing program runs, the disabled command(s) will not execute.
To re-enable the command(s), highlight the line(s) again, click on
Program>Instruction >
Enable Instruction.
19. Height Sense
- Opens a drop-down menu containing Height Sensor options.
Auto Height Sense On
- Inserts an Auto Height Sense On” command into your dispensing
program, which enables all height sensing. This is the default setting.
Auto Height Sense Off
- Inserts an Auto Height Sense Offcommand into your dispensing
program, which disables the height sensing operation and uses the last height recorded. Height
sensing will remain disabled until a Height Sense Oncommand occurs or the program is
restarted. If a Find Substrate Heightcommand occurs after this command, it will execute.
Set Height Sense Mode
- This command is automatically inserted at the beginning of the Main
Program, before the DO: Workpiece AT (xx,yy)command. If this command does not occur
in the Main Program, FmXP will issue an error and abort the run.
20. Pattern
- Opens a drop-down menu containing pattern-related commands.
Create
- Opens a dialog box for naming a new pattern.
Place
- Once you create a pattern, it does not automatically become part of your program. You
must insert the pattern by selecting Place Pattern.
Place Multipass Pattern
- Opens a Teach Window for placing a previously created Multipass
pattern at various locations on the workpiece.
Step and Repeat
- Opens a Teach Window in which you can specify the Step and Repeat
parameters for placing the selected program at multiple locations on a workpiece.
Loop Block
- Used to insert a Multipass pattern into a Main Dispensing Program.
Pass Block
- Used to setup the programming of a Multipass pattern.
21. Process Commands
- Accesses a drop-down menu containing the various Process Commands.
Find Substrate Height
- Determines workpiece height.
Purge
- Inserts a purge command into a program.
Nozzle Purge
- Adds a " Nozzle Purge" instruction to the program. Opens a dialog box to select
the Purge Location, Pulse On and OFF times, Purge Count, Valve Number, Do Height Sense at
Purge Location, and Use Active Air.
Measure Flow Rate
- Inserts a Measure Flow Ratecommand into a program.
Check CPJ Flowrate