Owner's manual

Running Production 8-3
8.4 Prompted Setup
Prompted Setup is a user-prompted routine to ensure proper offset parameters for the camera, needle,
height sensor, and purge/scale stations. Prompted Setup should be performed:
Prior to all production runs
After a valve has been removed or reinstalled
After a new needle has been placed on the valve assembly
After moving or focusing the camera
After moving or replacing the height sensor probe assembly
Anytime you are experiencing inaccurate dispensing
Part of Prompted Setup includes the Initial Setup procedure (whichever one is selected) as well as other
system preparation tasks. Refer to 4.3.8 Machine Offsets for instructions on selecting an initial setup
procedure.
NOTE The Century and M-600 Series Dispensing Systems support the original Prompted Setup
routine, as well as Scripted Prompted Setup. M-2000, X-1000 and Spectrum Series
Dispensing Systems support only Scripted Prompted Setup.
If you have a Dual-Action or a Dual-Bracket Dispensing Head, it is recommended that you
use the Scripted Prompted Setup described later in this section.
To perform the original prompted setup procedure:
1. Select
Setup Scripts Options from the Configuration Menu.
The Setup Scripts Options dialog box (Figure 8-2) opens.
Figure 8-2 Setup Scripts Options