Owner's manual

7-68 Advanced Programming
Table 7-3 Weight Calibration Window - Calibration Tab
Name Description
Calibration Parameters
Calibrate Button Runs the Advanced CPJ+ Calibration Routine.
Mg/LED
Enter the desired Target Weight per LED (or cell). Note: This is not the
same as milligrams per shot.
Max % Weight Deviation
Maximum percentage weight deviation. Iteration to converge when
weight per LED falls within these limits. The calibration results are saved
to the validation parameters and fluid file.
Desired Cell Weight Bias (%) Can be used to match readings with the external scale, if used.
Time Between Cells (ms)
Simulates production time between cells (or LEDs). Used for both
validation and calibration routines.
#LEDs for Calibration Number of LED dispenses to simulate.
Validation Parameters
Validation Button Used to validate parameters found during calibration routine.
Fluid Pressure (psi) Resulting pressure from calibration routine.
Shots/LED Resulting number of shots (dots) per LED from calibration routine.
Valve On Time (ms)
Resulting Jet Valve On Time from calibration routine. Stored to output
dot type in fluid file.
Valve Off Time (ms)
Resulting Jet Valve Off Time from calibration routine. Stored as dwell
time for output dot type in fluid file.
#LEDs for Calibration
Enter the number of LEDs to simulate using resulting calibration
parameters.
Display Text Toggles between graph and text display.
Fluid Pressure - Adjust Clicking on Adjust opens the Fluid Manager Air Pressure Settings tab.
Active Air Pressure - Adjust Clicking on Adjust opens the Fluid Manager Air Pressure Settings tab.
Nozzle Temperature Adjust Clicking on Adjust opens the Fluidmove Heater Control Window.
Purge Active Air Purges the active nozzle.